Speaker
Description
Large liquid xenon (LXe) detectors have become a leading technology in rare-event searches, including direct dark matter detection and searches for neutrinoless double beta decay.
A significant source of background in these experiments arises from the radioactive progeny of 222Rn, a noble gas that can emanate from detector surfaces. To achieve the target sensitivities of next-generation experiments such as XLZD, further radon mitigation techniques will be needed.
A novel radon mitigation technique based on electrochemically deposited surface coatings has recently been developed at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, achieving a thousandfold reduction in radon emanation from stainless steel samples. This work investigates the application of this technique in a large-scale liquid xenon detector, as well as its compatibility with the stringent radiopurity requirements of LXe detectors and its long-term stability under cryogenic operating conditions.
The coating is applied in collaboration with MPIK and evaluated in Xenoscope, a 2.6-m-long dual-phase time projection chamber (TPC) operated at the University of Zurich, which provides a representative environment for large-scale LXe detectors.
This contribution presents the current status of the coating and its validation in Xenoscope.