The J-PARC muon g−2/EDM experiment aims to precisely measure the muon anomalous magnetic moment and electric dipole moment using a low-emittance muon beam. Characterization of the longitudinal bunch structure is important for the development of the muon linear accelerator.
We developed a bunch width monitor (BWM) using a microchannel plate (MCP) detector to measure the time structure of accelerated muons. In June 2026, a beam test was conducted in the H2 area at J-PARC, where cooled muons were successfully accelerated to 0.3 MeV for the first time in this area.
Using the BWM, we observed the expected microbunch structure of muons accelerated by a 324 MHz radio-frequency quadrupole (RFQ). The relative populations of the microbunches showed a dependence on the RFQ phase, consistent with the trends predicted by simulations. The measured main-bunch width was also comparable in scale to the simulation results, although quantitative differences remain under investigation.
This poster presents the measurement of the accelerated muon bunch structure and its comparison with simulations.